Skip to main content
Browse Depth Notes
Donarun Das

equipment

How a Submersible Pressure Gauge Works

A bent tube, a link and two gears. Nothing in it measures gas.

±5 bar
accuracy EN 250 requires at 50 bar
2–3 mm
how far the tube tip moves
22 min
to drain an aluminium 80 through a cut gauge hose, one test

November 23, 2026 · 9 min read

Part 7 of 8 in How Scuba Gear Works · Previous: the balanced second stage · Next: the power inflator

The submersible pressure gauge (SPG) on the end of your high-pressure hose does not measure gas. It measures how far a curved metal tube has straightened under pressure, and a small gear train turns that movement into a needle position. The design is the Bourdon gauge, invented by the French engineer Eugène Bourdon in 1849 for steam engines.

The tube

Open the figure on its own page

Inside the case is a tube with a flattened, oval cross-section, bent into a curve. One end is fixed to the inlet and open to cylinder pressure. The other end is sealed and free to move.

When pressure enters, the flattened section tries to become round. Gauge maker WIKA describes what follows: the stresses this sets up increase the radius of the curve, and the end of the tube moves by around two or three millimetres. Take the pressure away and the tube springs back.

One dive gauge maker, Termo Industria, lists a copper-beryllium tube in a brass case.

The figure draws the tube as a single C, which is the textbook layout. I could not find a dive gauge maker that says whether its tube is a C or a coil of several turns. WIKA says C-shaped tubes are used up to about 60 bar and coiled ones above that, and Knight and Acott describe dive gauges as "coiled tubes that uncoil or recoil as the pressure within them changes". The principle is the same either way.

The movement

Two or three millimetres is too small to read, so it is multiplied.

A short link joins the free end of the tube to a pivoted arm with gear teeth along its edge, called a sector. The sector meshes with a small gear, the pinion, on the needle's shaft. A small movement at the link becomes a large rotation at the pinion. A fine hairspring keeps the teeth pressed together so the needle does not wobble.

In the figure, step to the link and gears section and press 50 bar, then 300 bar. The tube tip barely moves and the needle sweeps most of the dial.

How accurate it has to be

EN 250:2014, the European standard for open-circuit scuba, requires every set to have a pressure indicator and sets how far it may be out, tested as the pressure falls:

AtAllowed error
300 bar± 15 bar
200 bar± 10 bar
100 bar± 10 bar
50 bar± 5 bar

Mares and Termo Industria quote the same figures for their gauges. Oceanpro quotes ± 2.5 bar at 50 bar.

The standard also requires the scale to run to at least 20 percent above the cylinder's working pressure, the divisions to be no more than 10 bar apart, and the range below 50 bar to be "clearly differentiated to emphasize low air supply". That is the red band.

Plan with that tolerance in mind. A needle on 50 bar can mean 45. On an 11 litre cylinder that 5 bar is 55 litres of gas. Leave room for it in your reserve.

What goes wrong

A Bourdon gauge is a calibrated spring, and springs can be bent. Knight and Acott, reviewing gauge problems in the Diving Incident Monitoring Study, counted 37 incidents involving contents gauges, 10 of them with harm, and wrote that inaccurate gauges were one of the frequently reported causes of running out of air underwater.

Their practical points:

  • A gauge that has been dropped or shaken may no longer be reliable.
  • A gauge that does not return to zero when it is taken off the cylinder must be considered faulty.
  • There is no legal requirement to recalibrate a dive gauge, and the only convenient check is to compare it with another.

So compare it. When you analyse or check a cylinder at the fill station, note what their gauge says and what yours says. If they differ by more than the table above allows, yours goes for service.

Maker guidance on service varies. Oceanpro calls for a yearly inspection that verifies the dial, Mares for a service every other year or 200 dives, and Termo Industria says the gauge needs no special maintenance beyond checking the hose O-ring.

What a moving needle means

Watch the needle while you take a few hard breaths before you get in.

If it holds still, gas is reaching the regulator freely. If it drops on each breath and climbs back, the cylinder valve is only partly open. Knight and Acott: "Many divers are also unaware that fluctuation of the gauge needle when a breath is taken indicates that the cylinder is not fully turned on."

A report in a Divers Alert Network (DAN) annual summary shows what that looks like underwater. A diver with the valve open a quarter turn noticed laboured breathing at 9 m after 40 minutes, looked down, and saw the needle swinging between 1,600 psi and under 500.

A steady needle at the surface is not proof on its own, since a slightly open valve can keep up with a resting diver. Breathe hard when you test it. The valve itself is covered in how a cylinder valve works.

There is a second check both Mares and Termo Industria give. Pressurise the regulator, close the cylinder valve, and watch. The needle should stay where it is. If it falls, something is leaking.

Why a burst gauge hose is slow

The high-pressure hose carries full cylinder pressure, so it looks like the most dangerous hose on the regulator. It is the least urgent to lose.

EN 250 requires the outlet that feeds the gauge to pass no more than 100 litres a minute at 100 bar with nothing connected. Makers meet that with a very small hole at the hose fitting or in the port. The same hole softens the surge that hits the gauge when the valve is opened.

Advanced Diver Magazine timed how long an aluminium 80 took to empty from 3,000 psi through different failures:

FailureTime to empty
Severed high-pressure hose1,320 seconds (22 minutes)
Severed low-pressure hose81 to 83 seconds
Failed burst disc72 to 74 seconds

That is one test series from a trade magazine, so treat the exact figures with care. The scale of the difference fits the standard's flow limit.

A high-pressure leak is loud and alarming and gives you time to end the dive calmly. A low-pressure hose failure does not.

The small parts that leak

Where the hose meets the gauge there is a swivel so the gauge can turn. Inside it is a tiny hollow pin with an O-ring at each end, called the air spool. When those O-rings wear, a thin stream of bubbles comes from the swivel.

Because of the flow restriction upstream, the leak is small even when an O-ring has failed completely. It will not empty your cylinder in a dive. Replace the spool, or at least its O-rings, when it starts, and whenever you change the hose.

The plug on the back

Most gauges have a rubber plug in the back of the case. If the tube ruptures, high-pressure gas fills the case, and the plug pops out so the lens does not. EN 250 requires a mechanical gauge to have this kind of relief. Termo Industria says its plug opens when the pressure in the case passes 2.5 bar.

Do not cover the plug with a boot, a bracket or tape. The US Navy Diving Manual adds a habit worth copying: when you open the cylinder valve, turn the face of the gauge away from you and anyone else.

Transmitters

A wireless transmitter screws into the same high-pressure port and sends the pressure to your dive computer. Shearwater's Swift is rated to 300 bar with a stated accuracy of 5 percent of full scale, which is 15 bar.

Shearwater's own instructions say to use a first stage with at least two high-pressure ports so that a backup pressure gauge can be fitted, and warn that a failed transmitter may report more or less gas than is there, or nothing. I fit both.

References

  • CEN. EN 250:2014. Respiratory equipment: open-circuit self-contained compressed air diving apparatus. Requirements, testing and marking. Clauses 5.9.1 and 5.9.2.
  • Knight J, Acott CJ. Depth gauges, contents gauges and miscellaneous equipment problems reported in the Diving Incident Monitoring Study. SPUMS Journal. 2003;33(1):34–37.
  • Naval Sea Systems Command. U.S. Navy Diving Manual, Revision 7. 2016. Paragraphs 4-5.3.1 and 7-3.1.1.7.
  • Mares. Pressure gauge user's guide (Mission gauge), Rev. B. 2021.
  • Termo Industria. Submersible pressure gauge SPG series: instructions for use, NI 002-2016 Rev. 1. 2021.
  • Oceanpro. Analogue instrument user manual.
  • Shearwater Research. Swift operating instructions, Doc. 57025 Rev G. 2021.
  • WIKA. Bourdon tube pressure gauge: operating principle; and Eugène Bourdon and the history of the Bourdon gauge. blog.wika.com
  • Bowen C. Life ending seconds. Advanced Diver Magazine.
  • Dive Gear Express. High pressure swivel spindles, also known as air spools. TekTips.
  • Divers Alert Network. DAN Annual Diving Report 2016. Incident case summaries.

Train with me

Gas planning that allows for what your gauge cannot tell you is part of every technical course I teach. Enquire about training →

Common questions

How does a scuba pressure gauge work?

Cylinder pressure is fed into a flattened, curved metal tube that is sealed at its far end, called a Bourdon tube. Pressure makes the tube straighten slightly. A link and a pair of small gears magnify that movement of two or three millimetres into the sweep of the needle.

How accurate is a submersible pressure gauge?

EN 250:2014 requires a diving pressure gauge to read within 5 bar at 50 bar, within 10 bar at 100 and at 200 bar, and within 15 bar at 300 bar. Mares and Termo Industria quote the same figures for their gauges. A gauge that has been dropped may no longer meet them.

Why does my pressure gauge needle move when I breathe?

A needle that drops as you inhale and recovers as you stop means the cylinder valve is not fully open. Knight and Acott reported in the SPUMS Journal that many divers do not know this. Open the valve all the way and check again before you get in.

What happens if the high-pressure hose bursts?

The cylinder empties slowly. EN 250 limits the flow from the gauge port to 100 litres a minute at 100 bar. In one published test an aluminium 80 took 22 minutes to empty through a severed high-pressure hose, against about 80 seconds through a severed low-pressure hose.