title: "How a Scuba Second Stage Works"
description: "What happens inside a scuba second stage on every breath: diaphragm, lever, poppet and orifice, cracking effort, and why a downstream valve fails open."
canonical: "https://donarundas.com/depth-notes/equipment/how-a-scuba-second-stage-works"
author: "Donarun Das — TDI Trimix Instructor, KISS Sidewinder CCR Instructor"
category: "equipment"
published: "2026-11-23"
tags: ["regulators", "equipment", "second-stage"]
disclaimer: "Dive theory published by a working instructor for education. It is not medical advice and not a substitute for training. Decompression, gas, and depth decisions belong with your own training, your dive computer, and a dive medical officer."
license: "© Donarun Das. Quote with attribution and a link to the canonical URL."
---

# How a Scuba Second Stage Works

*Part 5 of 8 in How Scuba Gear Works · Previous: [the balanced piston first stage](https://donarundas.com/depth-notes/equipment/balanced-piston-first-stage) · Next: [the balanced second stage](https://donarundas.com/depth-notes/equipment/balanced-second-stage)*

The second stage is the part of the regulator you hold in your teeth. It takes gas from the hose at about 9.5 bar above the surrounding water pressure and hands it to you at the pressure of the water around you, only while you are inhaling. Four parts do the job: a diaphragm, a lever, a spring-loaded poppet and an orifice.

This note covers the classic unbalanced downstream design, the kind fitted to most rental regulators. The [balanced second stage](https://donarundas.com/depth-notes/equipment/balanced-second-stage) is the same valve with one change, and it makes more sense once you have this one clear.

## What happens on one breath

The case is a small chamber with a flexible silicone diaphragm across the front. Water is on one side of the diaphragm and the air you breathe is on the other.

When you inhale, the pressure inside the case drops a little below the water pressure outside. The water pushes the diaphragm inward. The diaphragm presses on a lever, and the lever pulls the poppet back off the orifice. Gas from the hose flows through the gap into the case and out through the mouthpiece. The harder you pull, the further the diaphragm travels and the wider the valve opens.

When you stop inhaling, the case fills back to ambient pressure, the diaphragm returns, and the spring pushes the poppet back onto the orifice. The US Navy Diving Manual puts it in one line: when the diver stops inhaling, the pressure on either side of the diaphragm is balanced again and the valve closes.

When you exhale, your breath leaves through a one-way exhaust valve at the bottom of the case. The purge button on the front cover pushes the diaphragm in by hand, which opens the valve without a breath. That is all it does.

Step through the figure's sections to see each part, then press the breathe button and watch the lever and poppet move.

## What "downstream" means and why it matters

The orifice is a hole with a sharp circular edge. The poppet carries a soft seat that presses against that edge. In a downstream valve the poppet sits on the low-pressure side of the orifice, so the gas in the hose is always trying to push it open. The spring is the only thing holding it shut.

EN 250, the European standard for open-circuit regulators, defines the two types by what they do when the pressure feeding them rises. A downstream demand valve "will open and let gas out with an increasing medium pressure". An upstream one "will close and not let gas out".

That difference decides how the regulator fails. If the first stage leaks or freezes and the pressure in the hose climbs, a downstream second stage is pushed open and free-flows. You get a lot of gas and a lot of noise, and you can still breathe from it while you sort the problem out or ascend. An upstream valve would be pushed shut harder, which is why the standard requires a separate relief valve on any regulator that uses one. Goble and Acott, reviewing 52 regulator incidents for the Diving Incident Monitoring Study, wrote that upstream valves "do not fail-safe".

## What cracking effort is

Cracking effort is the suction you have to make before the valve opens at all. EN 250 calls it the opening negative pressure: the respiratory pressure during inhalation required to open the inhalation valve.

It is tiny. Service documents state it in inches of water, measured with a manometer on the mouthpiece:

| Second stage | Design | Cracking effort |
|---|---|---|
| Scubapro R195 | unbalanced downstream | 1.3 to 1.5 inches of water (3.3 to 3.8 millibar) |
| Aqua Lung Conshelf XIV | unbalanced downstream | 0.6 to 1.5 inches of water |
| Scubapro S600 | air-balanced | 1.0 to 1.4 inches of water |

Those are bench figures on a freshly serviced regulator. They are set by two adjustments. The technician turns the orifice in or out until the seat only just seals, then sets the spring load on the poppet. Less spring gives a lighter breath, and too little gives a valve that leaks.

## Why the effort changes as the cylinder empties

In this design, hose pressure helps open the valve. The spring has to be strong enough to hold the poppet shut against the highest pressure the first stage will deliver.

If the pressure in the hose falls, that help is smaller, and your lungs make up the difference. A tool maker's service note says it directly: cracking effort increases as intermediate pressure decreases, and the other way round. Pair an unbalanced second stage with an [unbalanced first stage](https://donarundas.com/depth-notes/equipment/unbalanced-piston-first-stage), whose output drifts as the cylinder empties, and the regulator breathes slightly differently at the end of the dive than at the start.

I could not find a published figure for how large that change is on any real regulator. The figure above models it from assumed part sizes, and its caption says so. Use the two pressure buttons to see the direction of the effect, and do not read the millibar values as measurements.

## Why it free-flows at the surface

Gas leaving the orifice at speed is aimed at the mouthpiece. That jet lowers the pressure inside the case, which pulls the diaphragm in and holds the valve open with no effort from you. Scubapro calls its version Venturi Initiated Vacuum Assist (VIVA). It is the reason a good regulator feels as if it is feeding you once a breath has started.

It is also why a second stage can run away when it is out of your mouth. Scubapro's manual says that pressing the purge button with the mouthpiece out may trigger the effect and cause a free-flow, and that you can stop it by covering the mouthpiece with a finger, by putting the second stage in the water with the mouthpiece turned down, or by putting it in your mouth.

Most second stages have a switch for this. EN 250 calls it the dive/pre-dive control. Set it to pre-dive at the surface and to dive once you are under. The R195 has this switch and no other user adjustment.

## What the standard asks of it

EN 250:2014 tests a regulator on a breathing machine at 6 bar absolute, which is 50 m, moving 62.5 litres a minute through it in water at 10 °C. Under those conditions:

- work of breathing must not exceed 2.5 joules per litre (3.0 only for a regulator with a breathing-effort knob set to its stiffest)
- the pressure swing on inhalation and exhalation must stay within 25 millibar either side of ambient
- the regulator must not free-flow, apart from a brief burst of no more than ten seconds

You will often see 3.0 joules per litre quoted as the limit. That figure is from the 2000 edition of the standard.

Work of breathing rises with depth because the gas gets denser. That is a subject of its own: see [gas density and carbon dioxide build-up](https://donarundas.com/depth-notes/physiology/gas-density-and-co2-buildup).

## Cold water

A second stage can freeze open. Air arriving from the first stage is well below the water temperature, it chills the valve parts, and the moisture in your exhaled breath freezes onto them. Ice takes up the small amount of free play between the lever and the poppet, the valve cannot close fully, and the flow that follows makes everything colder.

Dive Lab, which tests regulators for the US Navy, reports that at high flow rates ice will often form inside most second stages even in water of 7 to 10 °C. The US Navy Diving Manual warns that a free-flow of as little as five seconds can start a freeze-up and tells divers to avoid purging the second stage in cold conditions. EN 250 treats anything below 10 °C as cold water and requires a regulator that is not rated for it to be marked "> 10 °C".

## What to check on your own

You cannot tune a second stage by feel, but you can spot one that needs a technician.

- A slow hiss or a trickle of bubbles from the mouthpiece means the seat is not sealing.
- A breath that takes a noticeable pull to start means the cracking effort is too high.
- A wet breath usually means a torn or folded diaphragm, a damaged exhaust valve or a split mouthpiece.

Goble and Acott found that free-flowing second stages in their incident set frequently followed a recent service. Breathe from a regulator in the water before the first dive after it comes back from the workshop.

Scubapro's current manual sets an overhaul every two years, or every year for regulators doing more than 100 dives a year. Other makers set different intervals, so check the manual for yours.

## References

- CEN. *EN 250:2014. Respiratory equipment: open-circuit self-contained compressed air diving apparatus. Requirements, testing and marking.* Clauses 3.7, 3.24, 3.25, 5.7.1, 5.7.2, 7.2.
- Naval Sea Systems Command. *U.S. Navy Diving Manual, Revision 7.* 2016. Sections 7-3.1.1 and 11-2.4.
- Goble S, Acott CJ. Regulator incidents: 52 incidents from the Diving Incident Monitoring Study. *SPUMS Journal.* 2003;33(1):30.
- Scubapro. *Regulators manual*, P/N 45101180 rev M. 2021. Sections 5.2, 7 and 8.2.
- Scubapro. *Maintenance procedure for R195 second stage.* Undated service document.
- Scubapro. *Repair guide: S600 and S550 second stages.* 2003.
- Aqua Lung America. *Technical maintenance manual: Conshelf XIV first and second stage.* Rev. 7/2004.
- Ward M. *Scuba Regulator Freezing: Chilling Facts and Risks Associated with Cold Water Diving.* Dive Lab, Inc. 2014. [divelab.com](https://divelab.com/wp-content/uploads/2025/12/ScubaRegulatorFreezing-ChillingFacts-4-9-14-Rev-Sec.-8.2-12-2-2025.pdf)
- Scuba Clinic Tools. *Adjusting downstream second stages.* Technical note. [scuba-clinic-tools.com](https://scuba-clinic-tools.com/blogs/technical-info/adjusting-downstream-second-stages)

### Train with me

Knowing what your regulator is doing, and what it does when it fails, is part of every technical course I teach. [Enquire about training →](https://donarundas.com/contact)

## Common questions

### How does a scuba second stage work?

When you inhale, pressure inside the case drops below the water pressure outside. The water pushes a flexible diaphragm inward, the diaphragm tips a lever, and the lever pulls a spring-loaded poppet off a small orifice. Gas at intermediate pressure flows in until the case is back at ambient pressure, the diaphragm relaxes and the spring shuts the valve.

### What is cracking effort on a regulator?

Cracking effort is the suction needed to open the second-stage valve at the start of a breath. EN 250 defines it as the respiratory pressure during inhalation required to open the inhalation valve. Manufacturer service documents set it at roughly 1.0 to 1.5 inches of water, about 2.5 to 3.8 millibar, on a serviced regulator.

### Why does a regulator free-flow instead of shutting off when it fails?

Most second stages use a downstream valve, which opens in the same direction the gas is pushing. If the first stage lets intermediate pressure climb, that pressure pushes the poppet off its seat and gas escapes, so the diver gets too much gas where an upstream valve would give none.

### Why does my regulator free-flow at the surface?

Once gas is moving fast through the case it creates a low-pressure area that holds the diaphragm in and keeps the valve open. Scubapro's manual says pressing the purge with the mouthpiece out of your mouth can start it. Cover the mouthpiece with a finger, turn it to face down in the water, or put it in your mouth, and it stops.

---

**Source:** [https://donarundas.com/depth-notes/equipment/how-a-scuba-second-stage-works](https://donarundas.com/depth-notes/equipment/how-a-scuba-second-stage-works)

**About the author:** Donarun Das is a TDI Trimix and KISS Sidewinder CCR instructor teaching technical and rebreather diving in the Maldives, Sri Lanka, and India. He holds the deepest verified civilian dive in India (110 m, open-circuit trimix, Lakshadweep, March 2026). Courses: https://donarundas.com/courses — enquiries: https://donarundas.com/contact

> Dive theory published by a working instructor for education. It is not medical advice and not a substitute for training. Decompression, gas, and depth decisions belong with your own training, your dive computer, and a dive medical officer.

## Sitemap