Fig 4Unbalanced second stageButtons below · arrow keysintermediate 9.8 bar · cracks at 3.5 mbar · closed
1 / 6The whole figure. Step through its sections with the arrows, or pick one.
Feed
Lever and poppet: the diaphragm tips the lever, the lever pulls the poppet off the orificeGas moving on an inhalationManometer: the mark is the cracking effort, the needle is the case on each breathMoulded case and coverSilicone: diaphragm, mouthpieceStainless steelPlastic poppet and diaphragm plateSoft seatChrome plateBrass, where it is cutRubber: hose, purge button, O-ringsIntermediate pressure, stopped at the orificeBreathing gas at ambient pressureAn unbalanced downstream second stage, the layout of a Scubapro R195, lying diaphragm-up and cut in half. Intermediate pressure pushes the poppet open through the orifice and the spring alone holds it shut, 22 N in this model. As the feed falls from 9.8 to 8.6 bar it helps less, and the effort to crack the valve rises from 3.5 to 6.3 mbar (1.4 to 2.5 inches of water). Published: 1.3–1.5 inches of water on a full cylinder. The orifice and diaphragm sizes are assumptions, the spring is set so the model gives the middle of that band at 9.8 bar, and the poppet's travel is drawn, not measured.