1 / 6The whole figure. Step through its sections with the arrows, or pick one.

Feed
Lever and poppet: the diaphragm tips the lever, the lever pulls the poppet off the orificeGas moving on an inhalationManometer: the mark is the cracking effort, the needle is the case on each breathMoulded case, cover and knobSilicone: diaphragm, mouthpieceStainless steelPlastic poppet and diaphragm plateSoft seatChrome plateBrass: where it is cut, and the balance chamberRubber: hose, purge button, O-ringsIntermediate pressure, led through the poppet to the balance chamberBreathing gas at ambient pressureA balanced second stage, the layout of a Scubapro S600, lying diaphragm-up and cut in half. The poppet is hollow: intermediate pressure passes through it into a balance chamber behind it and pushes it shut, cancelling most of what pushes it open at the orifice. A light spring does the rest, 6 N in this model, so the effort to crack the valve moves only from 3.0 to 3.5 mbar (1.2 to 1.4 inches of water) as the feed falls from 9.8 to 8.6 bar. Published: 1.0–1.4 inches of water. The orifice, balance stem and diaphragm sizes are assumptions, the spring is set so the model gives the middle of that band at 9.8 bar, and the poppet's travel is drawn, not measured.