Fig 8BCD power inflatorButtons below · keys I D Qvalves closed · no flow
1 / 6The whole figure. Step through its sections with the arrows, or pick one.
The button being pressed and the valve it opensGas moving at the bladder's pressureMoulded plastic bodyPlastic buttons and oral valveBrassChrome plateStainless steelSoft seatRubberSiliconeIntermediate pressure, held behind the inflate valveGas at the bladder's pressureA BCD power inflator cut in half, the layout of a generic K-style unit. Gas from the low-pressure hose waits at intermediate pressure under a small valve core, the kind used in a tyre valve, held shut by its own spring and by the gas behind it. The inflate button pushes a shaft across the airway onto the core's pin, and gas passes the core into the corrugated hose and the bladder. The end button pushes a larger spring-loaded valve off its seat, and the bladder vents through the mouthpiece; blow into the mouthpiece with it held and you inflate by mouth. A corroded core can stick open, and the way to stop the gas then is to pull the hose coupling off under pressure: the Disconnect hose button, or the Q key. Keys I and D press the two buttons. This figure shows which valve is open and nothing more: sizes and travels are drawn, not measured, and no flow rate is modelled.